Ich kann nicht mit einer NTP-Quelle synchronisieren, die von einem internen Router / einer internen Firewall stammt.
Jemand helfen?
ntppdate -d 192.168.92.82
6 Jun 11:57:30 ntpdate[5011]: ntpdate 4.1.2@1.892 Tue Feb 24 06:32:26 EST 2004 (1)
transmit(192.168.92.82)
receive(192.168.92.82)
transmit(192.168.92.82)
receive(192.168.92.82)
transmit(192.168.92.82)
receive(192.168.92.82)
transmit(192.168.92.82)
receive(192.168.92.82)
transmit(192.168.92.82)
192.168.92.82: Server dropped: strata too high
server 192.168.92.82, port 123
stratum 16, precision -19, leap 11, trust 000
refid [73.78.73.84], delay 0.02591, dispersion 0.00002
transmitted 4, in filter 4
reference time: 00000000.00000000 Thu, Feb 7 2036 6:28:16.000
originate timestamp: d1972e03.0ae02645 Mon, Jun 6 2011 11:44:19.042
transmit timestamp: d197311b.0ffac1d2 Mon, Jun 6 2011 11:57:31.062
filter delay: 0.02609 0.02591 0.02594 0.02596
0.00000 0.00000 0.00000 0.00000
filter offset: -792.020 -792.020 -792.020 -792.020
0.000000 0.000000 0.000000 0.000000
delay 0.02591, dispersion 0.00002
offset -792.020152
6 Jun 11:57:31 ntpdate[5011]: no server suitable for synchronization found
Bearbeiten
Der Server, mit dem ich synchronisiert werden soll, ist eine Firewall, und mir wurde jetzt mitgeteilt, dass keine Synchronisierung stattfindet. Also muss ich wohl wissen, ob ich meinen Server zwingen kann, mit einem Server zu synchronisieren, der Schicht 16 entspricht, dh nicht synchronisiert wurde. Ist das möglich ?